ESSER by Honeywell O2T/FSp multisensor fire detector IQ8Quad with isolator ESSER by Honeywell O2T/FSp multisensor fire detector IQ8Quad with isolator Honeywell O2T/FSp multisensor fire detector IQ8Quad with isolator In addition to smoke detection with conventional O²T multisensor technology,the detector is provided with a built-in voice alarm device a build-in flash lampand a built-in alarm signaling device. It can be set to eight different levels. DetectionMultisensor detectors with two built-in optical smoke sensors withdifferent scattered light angles as well as additional heat detector sensorevaluation for detecting everything from smouldering fires to open fires withconsistent response performance. Smoke sensor signal identification to ensuresmoke classification and reduction of false alarms caused, for instance, by watervapour or dust. Each detector is provided with an integrated isolator. Alarm signalingThe alarm signaling device is activated by the control panel. Nofurther short address needs to be allocated. It is programmed with tools 8000 asof software version 1.05. Alarm tone / speech message programming (depending on type)For detectorswith speech message and / or alarm tone function with up to five languageoptions, up to 4 signals can be programmed. Two signals are reserved for alarmsignaling and evacuation in the case of fire. Two further signals can beprogrammed for other events. Each signal can consist of up to four signalcomponents, enabling one signal to be programmed as a DIN tone combined withsubsequent speech messages in three different languages. Alarm tones can be chosen from a table with various tone types. For applicationin schools, a break signal to signify the breaks between class can be activated.When the basic setting is selected, signals / signal components can becontinuously repeated until the signaling function is interrupted by the controlpanel. They can also be programmed with a repetition rate of one to three times.Thus, the break signal in schools can be deliberately set to only one repetition. Inthe same way, the total signal can be set to continuous repetition, with the DINtone being played only once while subsequent speech messages are played upto three times. Sound pressure programmingThe sound level [dB(A)] can be set to eight levels, from approximately 64dB (A) toapproximately 92dB (A). Features Detection The reliable O²T multisensor principle for consistent response performance at the highest level of security against false alarms Flash Lamp Loop powered - no need for external power supply No additional short address Automatic synchronization of various IQ8Quad alarm signaling devices High flash energy Sounder Loop powered - no need for external power supply Individual control of the Sounder Tones can be used for other purposes in addition to warning of fire, making the device ideal for use in schools (school bell), etc. Soft start option, ideal for hospitals and nursing homes No additional short address Automatic synchronization of various IQ8Quad alarm signaling devices Maximum sound level: 92 dB (A) at 1 m Maximum sound pressure can be set Multiple signal components can be combined to one signal template Signal template and repetition rates can be set 20 different signal tones, incl. DIN-tone Low power consumption Speech message with sounder Loop powered - no need for external power supply No additional short address Automatic synchronization of various IQ8Quad alarm signaling devices Maximum sound level: 92 dB (A) at 1 m Maximum sound pressure can be set Multiple signal patterns can be combined to one signal Signal pattern and repetition rates can be set 20 different signal tones, incl. DIN-tone Speech messages can be played in up to 5 languages 5 alarm messages per languages are preprogrammed Up to 26 different languages are available Technical Data Operating voltage 8 ... 42 V DC Quiescent current @ 19 V DC 90 μA Quiescent current @ FACP battery approx. 500 μA @ 42 V Sound level max. 92 dB (A), +/- 2 db (A) @ 1m for DIN tone Signal flashing lamp red Luminous intensity max. 15.8 cd peak / 2.63 cd effective Lighting energy approx. 3 Y Area to be monitored max. 110 m² Height to be monitored max. 12 m Air velocity 0 ... 25.4 m/s Application temperature -20 °C ... 65 °C Storage temperature -25 °C ... 75 °C Type of protection IP43 (with base + options) Material ABS plastic Air humidity < 95 % Color white, similar to RAL 9010 Weight approx. 145 g Detector specification EN 54-7/-5 B/-17, CEA 4021 Specification EN54-3 acoustic signaling device Dimensions Ø: 117 mm H: 59 mmØ: 117 mm H: 67 mm (incl. base)  

ESSER by Honeywell O2T/FSp multisensor fire detector IQ8Quad with isolator

O2T/FSp multisensor fire detector IQ8Quad with isolator

In addition to smoke detection with conventional O²T multisensor technology,
the detector is provided with a built-in voice alarm device a build-in flash lamp
and a built-in alarm signaling device. It can be set to eight different levels.


DetectionMultisensor detectors with two built-in optical smoke sensors with
different scattered light angles as well as additional heat detector sensor
evaluation for detecting everything from smouldering fires to open fires with
consistent response performance. Smoke sensor signal identification to ensure
smoke classification and reduction of false alarms caused, for instance, by water
vapour or dust. Each detector is provided with an integrated isolator.


Alarm signalingThe alarm signaling device is activated by the control panel. No
further short address needs to be allocated. It is programmed with tools 8000 as
of software version 1.05.


Alarm tone / speech message programming (depending on type)For detectors
with speech message and / or alarm tone function with up to five language
options, up to 4 signals can be programmed. Two signals are reserved for alarm
signaling and evacuation in the case of fire. Two further signals can be
programmed for other events. Each signal can consist of up to four signal
components, enabling one signal to be programmed as a DIN tone combined with
subsequent speech messages in three different languages.


Alarm tones can be chosen from a table with various tone types. For application
in schools, a break signal to signify the breaks between class can be activated.
When the basic setting is selected, signals / signal components can be
continuously repeated until the signaling function is interrupted by the control
panel. They can also be programmed with a repetition rate of one to three times.
Thus, the break signal in schools can be deliberately set to only one repetition. In
the same way, the total signal can be set to continuous repetition, with the DIN
tone being played only once while subsequent speech messages are played up
to three times.


Sound pressure programming
The sound level [dB(A)] can be set to eight levels, from approximately 64dB (A) to
approximately 92dB (A).

Features

Detection
  • The reliable O²T multisensor principle for consistent response performance at the highest level of security against false alarms

    Flash Lamp

    • Loop powered - no need for external power supply
    • No additional short address
    • Automatic synchronization of various IQ8Quad alarm signaling devices
    • High flash energy

    Sounder

    • Loop powered - no need for external power supply
    • Individual control of the Sounder
    • Tones can be used for other purposes in addition to warning of fire, making the device ideal for use in schools (school bell), etc.
    • Soft start option, ideal for hospitals and nursing homes
    • No additional short address
    • Automatic synchronization of various IQ8Quad alarm signaling devices
    • Maximum sound level: 92 dB (A) at 1 m
    • Maximum sound pressure can be set
    • Multiple signal components can be combined to one signal template
    • Signal template and repetition rates can be set
    • 20 different signal tones, incl. DIN-tone
    • Low power consumption
    • Speech message with sounder
    • Loop powered - no need for external power supply
    • No additional short address
    • Automatic synchronization of various IQ8Quad alarm signaling devices
    • Maximum sound level: 92 dB (A) at 1 m
    • Maximum sound pressure can be set
    • Multiple signal patterns can be combined to one signal
    • Signal pattern and repetition rates can be set
    • 20 different signal tones, incl. DIN-tone
    • Speech messages can be played in up to 5 languages
    • 5 alarm messages per languages are preprogrammed
    • Up to 26 different languages are available

    Technical Data

    Operating voltage 8 ... 42 V DC
    Quiescent current @ 19 V DC 90 μA
    Quiescent current @ FACP battery approx. 500 μA @ 42 V
    Sound level max. 92 dB (A), +/- 2 db (A) @ 1m for DIN tone
    Signal flashing lamp red
    Luminous intensity max. 15.8 cd peak / 2.63 cd effective
    Lighting energy approx. 3 Y
    Area to be monitored max. 110 m²
    Height to be monitored max. 12 m
    Air velocity

    0 ... 25.4 m/s

    Application temperature

    -20 °C ... 65 °C

    Storage temperature -25 °C ... 75 °C
    Type of protection IP43 (with base + options)
    Material ABS plastic
    Air humidity < 95 %
    Color white, similar to RAL 9010
    Weight approx. 145 g
    Detector specification EN 54-7/-5 B/-17, CEA 4021
    Specification EN54-3 acoustic signaling device
    Dimensions

    Ø: 117 mm H: 59 mm
    Ø: 117 mm H: 67 mm (incl. base)

     

    O2T/FSp multisensor fire detector IQ8Quad with isolator

    In addition to smoke detection with conventional O²T multisensor technology,
    the detector is provided with a built-in voice alarm device a build-in flash lamp
    and a built-in alarm signaling device. It can be set to eight different levels.


    DetectionMultisensor detectors with two built-in optical smoke sensors with
    different scattered light angles as well as additional heat detector sensor
    evaluation for detecting everything from smouldering fires to open fires with
    consistent response performance. Smoke sensor signal identification to ensure
    smoke classification and reduction of false alarms caused, for instance, by water
    vapour or dust. Each detector is provided with an integrated isolator.


    Alarm signalingThe alarm signaling device is activated by the control panel. No
    further short address needs to be allocated. It is programmed with tools 8000 as
    of software version 1.05.


    Alarm tone / speech message programming (depending on type)For detectors
    with speech message and / or alarm tone function with up to five language
    options, up to 4 signals can be programmed. Two signals are reserved for alarm
    signaling and evacuation in the case of fire. Two further signals can be
    programmed for other events. Each signal can consist of up to four signal
    components, enabling one signal to be programmed as a DIN tone combined with
    subsequent speech messages in three different languages.


    Alarm tones can be chosen from a table with various tone types. For application
    in schools, a break signal to signify the breaks between class can be activated.
    When the basic setting is selected, signals / signal components can be
    continuously repeated until the signaling function is interrupted by the control
    panel. They can also be programmed with a repetition rate of one to three times.
    Thus, the break signal in schools can be deliberately set to only one repetition. In
    the same way, the total signal can be set to continuous repetition, with the DIN
    tone being played only once while subsequent speech messages are played up
    to three times.


    Sound pressure programming
    The sound level [dB(A)] can be set to eight levels, from approximately 64dB (A) to
    approximately 92dB (A).

    Features

    Detection
    • The reliable O²T multisensor principle for consistent response performance at the highest level of security against false alarms

      Flash Lamp

      • Loop powered - no need for external power supply
      • No additional short address
      • Automatic synchronization of various IQ8Quad alarm signaling devices
      • High flash energy

      Sounder

      • Loop powered - no need for external power supply
      • Individual control of the Sounder
      • Tones can be used for other purposes in addition to warning of fire, making the device ideal for use in schools (school bell), etc.
      • Soft start option, ideal for hospitals and nursing homes
      • No additional short address
      • Automatic synchronization of various IQ8Quad alarm signaling devices
      • Maximum sound level: 92 dB (A) at 1 m
      • Maximum sound pressure can be set
      • Multiple signal components can be combined to one signal template
      • Signal template and repetition rates can be set
      • 20 different signal tones, incl. DIN-tone
      • Low power consumption
      • Speech message with sounder
      • Loop powered - no need for external power supply
      • No additional short address
      • Automatic synchronization of various IQ8Quad alarm signaling devices
      • Maximum sound level: 92 dB (A) at 1 m
      • Maximum sound pressure can be set
      • Multiple signal patterns can be combined to one signal
      • Signal pattern and repetition rates can be set
      • 20 different signal tones, incl. DIN-tone
      • Speech messages can be played in up to 5 languages
      • 5 alarm messages per languages are preprogrammed
      • Up to 26 different languages are available

      Technical Data

      Operating voltage 8 ... 42 V DC
      Quiescent current @ 19 V DC 90 μA
      Quiescent current @ FACP battery approx. 500 μA @ 42 V
      Sound level max. 92 dB (A), +/- 2 db (A) @ 1m for DIN tone
      Signal flashing lamp red
      Luminous intensity max. 15.8 cd peak / 2.63 cd effective
      Lighting energy approx. 3 Y
      Area to be monitored max. 110 m²
      Height to be monitored max. 12 m
      Air velocity

      0 ... 25.4 m/s

      Application temperature

      -20 °C ... 65 °C

      Storage temperature -25 °C ... 75 °C
      Type of protection IP43 (with base + options)
      Material ABS plastic
      Air humidity < 95 %
      Color white, similar to RAL 9010
      Weight approx. 145 g
      Detector specification EN 54-7/-5 B/-17, CEA 4021
      Specification EN54-3 acoustic signaling device
      Dimensions

      Ø: 117 mm H: 59 mm
      Ø: 117 mm H: 67 mm (incl. base)

       

      PAYMENTS & SHIPPING

      Payments

      As of now, we accept payments through offline bank deposits or PayPal. Personal and bank cheques and money order payments require a period of waiting before your payment will arrive and can be processed before your order can be shipped.

      For payments via bank deposits, use your order number as a reference when processing your payment. Please notify us via email at info@rockford.com.ph when you have made your deposit so we can start processing your order

       

      ORDERS

      After you've placed your order and checked out, we will automatically send you an email confirming your purchase. We will send you another email informing you that your order has already been shipped.

      What are the shipping companies you use to ship out orders?

      In-house delivery team, Grab, and Lalamove

       

      SHIPPING FEES, TIME AND AREAS

      When will my order be shipped?

      Through third-party logistics, we are able to ship nationwide. It would typically take seven (7) to fifteen (15) business days for us to ship your order if you are outside Metro Manila. Otherwise, we usually send your order within three (3) to five (5) business days if you are in Metro Manila. The faster you make your transaction, the faster you receive your order.

      You will be able to track your order through our platforms and receive relevant updates on its status via email. When your order has already been packed and shipped, it will be marked as "Shipped".

      Rockford is not liable to any late delivery and that delivery times indicated are only based on guidelines. Uncontrollable events, such as natural disasters can greatly affect the expected delivery time. We ask for patience in times like this as we will do our best to deliver and update you.

      The stated delivery times are only guidelines and Rockford Marketing Corporation is not liable for any failed deliveries per the said times. Aside from that, uncontrollable events, such as natural disasters, can affect your order's delivery time. During these times, please be patient, and we will do our best to update you on your purchase.

      How much is the shipping fee for an item?

      For Metro Manila orders:
      Free shipping for orders worth Php 5,000 and above
      For orders below Php 5k, a flat rate shipping of Php 150 will apply

      Customs

      We also want to let you know that we have partnered with foreign brands and some products may be shipped from outside the country. Please be advised that SRPs are subject to change without prior notice. This may be  because of change or taxes and importation fee.

      Order Cancellation

      You can cancel your order if the item has not been dispatched from our office. Just have to contact us via email, info@rockford.com.ph or call us at 8245-3133 (loc. 120).

      Warranties and Returns

      All of our products cover a one-year warranty. If you receive a damaged or defective product, or it was damaged within a year of your purchase, you can bring it to our office at 722 Moriones St. cor Juan Luna, Tondo Manila. In order to return your product, you must provide the following: 

      • Actual product with packaging still intact 
      • Sales invoice of the said product

      Note: Please send us an email at panasonic.service@rockford.com.ph  and wait for our confirmation before coming to our office. 

      Lastly, if you received the wrong product/s, we encourage you to contact us immediately so we can handle the problem right away. Shipping costs are on us!